- Status
- In Force
- Penalty ceiling
- Regulated
Does it bind you?
Business-side roles with duties under this instrument.
Operator9
Responsible Person9
Any Person2
Employer2
Other Acts binding the same actors
If a role above is yours, these are the other instruments that most often bind it.
Operator — also bound by 746 other Acts
Regulation (EU) No 965/2012 (Air Operations)
203 duties
Space Industry Regulations 2021
76 duties
Responsible Person — also bound by 108 other Acts
MH(CT)(S)A 2003
30 duties
Any Person — also bound by 2340 other Acts
Human Medicines Regulations 2012
184 duties
Merchant Shipping Act 1995
144 duties
Insolvency (England and Wales) Rules 2016
104 duties
Communications Act 2003
92 duties
Road Traffic Act 1988
92 duties
Employer — also bound by 682 other Acts
What it requires
Regulations creating concrete business duties or carrying penalties, grouped as the instrument is structured. Titles link to the source text — blue means you’re leaving for legislation.gov.uk.
s.004
General duty
Regulated
- Ensure installation integrity at all times so far as is reasonably practicableResponsible Person
s.005
Design of an installation
Regulated
- Ensure offshore installation designs meet safety and integrity requirementsResponsible Person
s.006
Work to an installation
Regulated
- Ensure integrity of offshore installation during all work activitiesResponsible Person
s.007
Operation of an installation
Regulated
- Set and record safe operating limits for your offshore installationResponsible Person
s.008
Maintenance of integrity
Regulated
- Maintain the integrity of your offshore installation with periodic assessments and remedial workResponsible Person
s.009
Reporting of danger to an installation
Regulated
- Report significant threats to your offshore installation within 10 daysResponsible Person
s.010
Decommissioning and dismantlement
Regulated
- Maintain structural integrity during decommissioning and dismantlingResponsible Person
s.011
Helicopter landing area
Regulated
- Ensure helicopter landing area is safe and adequate for all weather operationsResponsible Person
s.012
Additional requirements
Regulated
- Comply with additional safety requirements for offshore installationsResponsible Person
s.013
General duty
Regulated
- Design and operate wells to prevent fluid escape and protect health and safetyOperator
s.014
Assessment of conditions below ground
Regulated
- Assess underground conditions before well design and keep under reviewOperator
s.015
Design with a view to suspension and abandonment
Regulated
- Design wells so they can be safely suspended or abandonedOperator
s.016
Materials
Regulated
- Ensure well materials are suitable for design purposesOperator
s.017
Well control
Regulated
- Provide and deploy well control equipment to prevent blowoutsOperator
s.018
Arrangements for examination
Regulated
- Set up written examination arrangements for wellsOperator
s.019
Provision of drilling etc. information
Regulated
- Send weekly reports to the Department for well operationsOperator
s.021
Information, instruction, training and supervision
Regulated
- Ensure workers are fully trained and supervised to reduce risksOperator
10 other provisions — procedural and definitional
s.001
Citation and commencement
s.002
Interpretation
s.003
Application
s.020
Co-operation
s.022
Defence
s.023
Certificates of exemption
s.024
Transitional provision
s.025
Repeal of section 3 of the Mineral Workings (Offshore Installations) Act 1971
s.026
Modifications of statutory provisions
s.027
Revocation
Schedules
Schedules
5 of 79 shown
s.sch001
Organisation of the installation
Regulated
- Design installation layout to reduce risk as low as reasonably practicableAny Person
s.sch001
Floors, walls and ceilings of rooms
Regulated
- Ensure floors are safe, stable and non-slipperyAny Person
s.sch001
Traffic routes
Regulated
- Ensure safe traffic routes to and from workplacesOperator
s.sch001
When workers are employed at workstations outdoors, such workstations must...
Regulated
- Arrange outdoor workstations to protect workers from weather, noise, falls, and hazardsEmployer
s.sch001
Room temperature
Regulated
- Maintain reasonable temperature in enclosed workplaces during working hoursEmployer
74 other schedules
s.sch001
The temperature in rest areas, changing rooms, rooms containing facilities...
s.sch001
Sunlight let into workplaces via any window or skylight shall...
s.sch001
Enclosed workplaces must be adequately insulated against heat, bearing in...
s.sch001
The surfaces of floors, walls and ceilings in rooms must...
s.sch001
Transparent or translucent surfaces
s.sch001
Roofs
s.sch001
Natural and artificial lighting
s.sch001
Workplaces must, as far as possible, receive sufficient natural light...
s.sch001
Lighting installations in workplaces and in passageways must be placed...
s.sch001
An installation shall be kept sufficiently clean, with any hazardous...
s.sch001
Workplaces in which persons are especially exposed to risks in...
s.sch001
Windows and skylights
s.sch001
It must be possible to clean windows and skylights without...
s.sch001
Doors and gates
s.sch001
Transparent doors must be appropriately marked at a conspicuous level....
s.sch001
Swing doors and gates must be transparent or have see-through...
s.sch001
Sliding doors must be fitted with a safety device to...
s.sch001
Doors and gates opening upwards must be fitted with a...
s.sch001
Doors for pedestrians must be provided in the immediate vicinity...
s.sch001
Power-operated doors and gates must function without risk of accident...
s.sch001
Arrangements shall exist for the collection at source and removal,...
s.sch001
When chains or similar devices are used to prevent access...
s.sch001
Traffic routes must be sufficient in number, in suitable positions,...
s.sch001
If means of transport are used on traffic routes, a...
s.sch001
Sufficient clearance must be allowed between vehicle traffic routes and...
s.sch001
Traffic routes must be clearly identified for the protection of...
s.sch001
Danger areas
s.sch001
Room dimensions and air space in rooms — freedom of movement in the workstation
s.sch001
The dimensions of the unoccupied area at the workstation must...
s.sch001
Rest rooms
s.sch001
Workstations must be designed and constructed with a view to...
s.sch001
Paragraph 39 does not apply if the workers are employed...
s.sch001
Rest rooms must be large enough and equipped with an...
s.sch001
If working hours are regularly and frequently interrupted and there...
s.sch001
Appropriate measures should be taken for the protection of non-smokers...
s.sch001
Outdoor workplaces
s.sch001
Workplaces outdoors must be adequately lit by artificial lighting if...
s.sch001
Pregnant women and nursing mothers
s.sch001
People with disabilities
s.sch001
Sanitary facilities
s.sch001
A supply of fresh or purified air shall be maintained...
s.sch001
Changing rooms must be easily accessible, be of sufficient capacity...
s.sch001
Changing rooms must be sufficiently large and have facilities to...
s.sch001
If circumstances so require, lockers for work clothes must be...
s.sch001
Provision must be made to enable wet work clothes to...
s.sch001
Provision must be made for separate changing rooms or separate...
s.sch001
If changing rooms are not required under paragraph 49, each...
s.sch001
Showers and washing facilities
s.sch001
Lavatories and washbasins
s.sch001
Provision must be made for separate lavatories or separate use...
s.sch001
Accommodation
s.sch001
If a mechanical ventilation system is used, it must be...
s.sch001
Accommodation must contain sufficient beds or bunks for the number...
s.sch001
Any room designated as sleeping accommodation— (a) must not be...
s.sch001
Accommodation must include a sufficient number of showers and washing...
s.sch001
Showers must be sufficiently spacious to permit each worker to...
s.sch001
Accommodation must be equipped with a sufficient number of lavatories...
s.sch001
Where there are both men and women on an installation...
s.sch001
Accommodation and its plant must be maintained to adequate standards...
s.sch001
Noise and vibration of plant
s.sch001
If air-conditioning or mechanical ventilation systems are used, they must...
s.sch001
Any deposit or dirt likely to create an immediate danger...
s.sch002
In regulation 2 of the 1993 Regulations—
s.sch002
In Schedule 6 to the 1993 Regulations there shall be...
s.sch002
After Schedule 6 to the 1993 Regulations there shall be...
s.sch002
After Schedule 8 to the 1993 Regulations there shall be...
s.sch002
There shall be substituted for paragraph (4) of regulation 7...
s.sch002
There shall be added to regulation 10 of the 1993...
s.sch002
After regulation 12 of the 1993 Regulations there shall be...
s.sch002
After paragraph (2) of regulation 14 of the 1993 Regulations...
s.sch002
In regulation 14(3) of the 1993 Regulations, for the words...
s.sch002
After regulation 14 of the 1993 Regulations there shall be...
s.sch002
After paragraph 9 of Schedule 2 to the 1993 Regulations...
s.sch002
After paragraph 7 of Schedule 3 to the 1993 Regulations...
Duty extraction and severity labels are Guvnor’s analysis of the instrument, not the instrument itself. Always verify against the linked source text.