- Status
- In Force
- Penalty ceiling
- Regulated
Does it bind you?
Business-side roles with duties under this instrument.
Manufacturer7
Any Person1
Conformity Assessment Body1
Plus 4 duties on the regulator, Crown ministers and public bodies — folded into the section list below.
Other Acts binding the same actors
If a role above is yours, these are the other instruments that most often bind it.
Manufacturer — also bound by 502 other Acts
Measuring Instruments Regulations 2016
85 duties
Human Medicines Regulations 2012
75 duties
Any Person — also bound by 2340 other Acts
Human Medicines Regulations 2012
184 duties
Merchant Shipping Act 1995
144 duties
Insolvency (England and Wales) Rules 2016
104 duties
Communications Act 2003
92 duties
Road Traffic Act 1988
92 duties
Conformity Assessment Body — also bound by 47 other Acts
Lifts Regulations 2016
28 duties
Radio Equipment Regulations 2017
27 duties
Explosives Regulations 2014
22 duties
What it requires
Regulations creating concrete business duties or carrying penalties, grouped as the instrument is structured. Titles link to the source text — blue means you’re leaving for legislation.gov.uk.
s.011
Application to be made to a single notified body
Regulated
- Do not submit duplicate EC type-examination applicationsAny Person
s.012
Refusal of EC type-examination certificate
Regulated
- Notified body must allow representations before refusing EC type-examination certificateConformity Assessment Body
s.013
Withdrawal of EC type-examination certificate
Regulated
Other duties (1) — Crown / regulator
- Notified body must withdraw certificate if conditions breached or standards not metStatutory regulator
s.014
Quality system approval
Regulated
- Obtain and maintain an approved quality system for gas appliances or fittingsManufacturer
s.015
Withdrawal of quality system approval
Regulated
Other duties (1) — Crown / regulator
- Notified bodies must follow due process when withdrawing quality system approvalStatutory regulator
s.017
EC verification (individual appliances and fittings)
Regulated
Other duties (1) — Crown / regulator
- Notified bodies must examine and test appliances/fittings submitted for EC verificationStatutory regulator
s.018
EC verification by batch (statistical method)
Regulated
- Do not supply gas appliances that fail batch verification, and retain the EC certificate of conformityManufacturer
s.020
Refusal to issue certificate of conformity
Regulated
Other duties (1) — Crown / regulator
- Notified body must hear applicant and give written reasons for refusalStatutory regulator
s.021
EC declaration of conformity to type (type examination)
Regulated
- Issue EC declaration of conformity for certified gas appliances and fittingsManufacturer
s.022
Surveillance by notified bodies
Regulated
- Appoint notified body and cooperate with EC surveillance before issuing conformity declarationManufacturer
s.024
EC mark to be affixed to appliances and fitting certificate to be supplied with fittings
Regulated
- Affix EC mark to appliances and supply fitting certificatesManufacturer
20 other provisions — procedural and definitional
sch. 1
sch. 1
s.001
Citation, commencement and revocation
s.002
Interpretation
s.003
Essential requirements
s.004
Application of Regulations
s.005
Appointment and functions of notified bodies
s.006
Fees
s.007
Appliances and fittings to satisfy the essential requirements and to be safe
s.008
Obligation on suppliers of appliances and fittings
s.009
Application of regulations 7 and 8
s.010
EC type-examination
s.016
EC declaration of conformity (guarantee of product or production quality)
s.019
EC unit verification
s.023
Failure to comply with Regulations: powers of notified bodies
s.025
Conformity with other directives etc.
s.026
Duties of enforcement authorities
s.027
Offences relating to domestic animals and to property
s.028
Proceedings
s.029
Requirement to give information about appliance which does not bear the EC mark
s.030
Regulations to be treated as safety regulations within the meaning of the
Schedules
Schedules
2 of 38 shown
s.sch003
The properties of materials that are important for safety must...
Regulated
- Guarantee safety-critical material properties for gas appliancesManufacturer
s.sch003
The surface temperature of knobs and levers of appliances intended...
Regulated
- Ensure knobs and levers don't get dangerously hotManufacturer
36 other schedules
s.sch003
Preliminary remark
s.sch003
Appliances must be so designed and built as to operate...
s.sch003
When placed on the market, all appliances must: be accompanied...
s.sch003
The technical instructions intended for the installer must contain all...
s.sch003
The instructions for use and servicing intended for the user...
s.sch003
The warning notices on the appliance and its packaging must...
s.sch003
Fittings intended to be part of an appliance must be...
s.sch003
Materials must be appropriate for their intended purpose and must...
s.sch003
General
s.sch003
Appliances must be so constructed that, when used normally, no...
s.sch003
If an appliance is equipped with safety and controlling devices,...
s.sch003
All parts of appliances which are set or adjusted at...
s.sch003
Levers and other controlling and setting devices must be clearly...
s.sch003
Condensation produced at the start-up and/or during use must not...
s.sch003
Appliances must be so designed and constructed as to minimise...
s.sch003
Appliances must be so constructed that water and inappropriate air...
s.sch003
In the event of a normal fluctuation of auxiliary energy,...
s.sch003
Abnormal fluctuation or failure of auxiliary energy or its restoration...
s.sch003
Appliances must be so designed and constructed as to obviate...
s.sch003
All pressurised parts of an appliance must withstand the mechanical...
s.sch003
Appliances must be so designed and constructed that failure of...
s.sch003
Unburned gas release
s.sch003
Appliances must be so constructed that the gas leakage rate...
s.sch003
Appliances must be so constructed that gas release during ignition...
s.sch003
Appliances intended to be used in indoor spaces and rooms...
s.sch003
Ignition Appliances must be so constructed that, when used normally:...
s.sch003
Combustion
s.sch003
Appliances must be so constructed that, when used normally, flame...
s.sch003
Appliances must be so constructed that, when used normally, there...
s.sch003
Appliances connected to a flue for the dispersal of combustion...
s.sch003
Independent flueless domestic heating appliances and flueless instantaneous water heaters...
s.sch003
Rational use of energy Appliances must be so constructed as...
s.sch003
Temperatures
s.sch003
Parts of the appliance which are intended to be placed...
s.sch003
The surface temperatures of external parts of appliances intended for...
s.sch003
Foodstuffs and water used for sanitary purposes Without prejudice to...
Duty extraction and severity labels are Guvnor’s analysis of the instrument, not the instrument itself. Always verify against the linked source text.