- Status
- In Force
- Penalty ceiling
- Regulated
Does it bind you?
Business-side roles with duties under this instrument.
Operator2
Trader1
Other Acts binding the same actors
If a role above is yours, these are the other instruments that most often bind it.
Operator — also bound by 746 other Acts
Regulation (EU) No 965/2012 (Air Operations)
203 duties
Space Industry Regulations 2021
76 duties
Trader — also bound by 825 other Acts
Value Added Tax Regulations 1995
416 duties
Companies Act 2006
243 duties
Companies Act 1985
85 duties
What it requires
Regulations creating concrete business duties or carrying penalties, grouped as the instrument is structured. Titles link to the source text — blue means you’re leaving for legislation.gov.uk.
s.art006
Leasing of railway to Company
Regulated
- Comply with all statutory obligations of the Council for the railway during the leaseTrader
11 other provisions — procedural and definitional
s.art001
Citation and commencement
s.art002
Interpretation
s.art003
Incorporation and modification of enactments
s.art004
Transfer of rights,
s.art005
Power to construct railway
s.art007
Sub-letting of railway to Bodmin Company
s.art008
Gauge of railway and motive power
s.art009
Level crossings
s.para.10
A portion (10,060 metres in length) of the former Bodmin...
s.para.104
Signs shall be provided on both sides of the railway...
s.para.11
commencing in the parish of Lanivet at Boscarne Junction on...
Schedules
Schedules
2 of 34 shown
s.sch003
Drivers shall bring their trains to a halt at the...
Regulated
- Drivers must stop at stop boards, wait for signals, and sound whistle before proceedingOperator
s.sch003
The operator shall give notice in writing to the Secretary...
Regulated
- Notify Secretary of State when crossing provisions are metOperator
32 other schedules
s.sch003
A. Particulars of the Barriers and other Protective Equipment
s.sch003
A traffic light signal of the size, colour and type...
s.sch003
An audible warning device shall be provided on or adjacent...
s.sch003
A reflectorised stop line of the size, colour and type...
s.sch003
Where the specified road passes over the crossing, reflectorised edge...
s.sch003
The centre line of the carriageway shall be marked on...
s.sch003
There shall be a control point on each railway approach...
s.sch003
Each control point shall have a keyswitch to energise the...
s.sch003
Lighting shall be provided as necessary so that during the...
s.sch003
A stop board of standard railway design displaying the words...
s.sch003
A lamp shall be provided on the western railway approach...
s.sch003
When lowered the barriers shall be as nearly horizontal as...
s.sch003
A stop board of standard railway design displaying the words...
s.sch003
A driver’s indicator shall be provided on each railway approach...
s.sch003
An advance warning board of standard railway design shall be...
s.sch003
Two independent power supplies shall be provided at the crossing,...
s.sch003
Cattle-cum-trespass guards of standard railway design shall be provided adjacent...
s.sch003
B. Conditions and Requirements to be observed by the Operator.
s.sch003
The lifting barriers shall be kept in the fully raised...
s.sch003
Visual indicators shall be provided at each control point. The...
s.sch003
When the keyswitch is operated to energise the control point...
s.sch003
When the ‘lower’ push-button of the control point is pressed...
s.sch003
When the barriers are fully lowered their uppermost surfaces shall...
s.sch003
The intermittent red lights shall continue to show until the...
s.sch003
Drivers shall bring their trains to a halt at the...
s.sch003
If any lifting barrier fails to rise from the lowered...
s.sch003
When in the fully raised position the barriers shall be...
s.sch003
The barriers shall be as light as possible but shall...
s.sch003
The barriers shall display on both front and rear faces...
s.sch003
Suitable screening shall be provided for each barrier machine to...
s.sch003
Two electric lamps, each of not less than 5 watts...
s.sch003
There shall be an additional swinging barrier on each side...
Duty extraction and severity labels are Guvnor’s analysis of the instrument, not the instrument itself. Always verify against the linked source text.