Who has these duties
The Control of Electromagnetic Fields at Work Regulations 2016 apply in England, Wales and Scotland. They place duties on an employer towards its own employees while they are at work. Northern Ireland has its own Regulations that impose equivalent duties.
An electromagnetic field (EMF) is a static electric, static magnetic or time-varying electric, magnetic or electromagnetic field with a frequency of up to 300 GHz. The Health and Safety Executive (HSE) says electrical or electronic equipment produces one whenever it is used, and that EMFs are present in virtually all workplaces.
HSE says most employers need take no additional action to reduce the risk from EMFs. HSE says this is because either the EMF levels in their workplaces are already safe, or the levels and risks where employees may be exposed to higher levels have already been assessed and managed. HSE names health care, energy distribution, engineering, broadcasting, transport and telecommunications as sectors with significant exposure. It says the risks there are generally well understood and well managed.
HSE's view does not remove the duty to assess exposure. The Regulations do not apply to the master or crew of a ship, or to their employer, for normal shipboard activities carried out solely by the crew under the master's direction. A ship includes every vessel used in navigation other than one forming part of Her Majesty's Navy.
Assess the field levels employees may be exposed to
You must make a suitable and sufficient assessment of the levels of EMF to which your employees may be exposed. The Regulations set no size threshold for this duty.
Where the duty to keep exposure within the exposure limit values applies, the assessment must show whether you comply with it. Use calculations and measurements if necessary.
You may assess exposure against the action levels (ALs) in the Schedule to show that specific exposure limit values (ELVs) are not exceeded. Each AL table in the Schedule states which ELVs are met if the field stays at or below that AL. Exposure above an AL may still be below the ELV, but you then have to assess further to find out.
The assessment may take into account:
- emission information and other safety related data from the manufacturer or distributor of the equipment
- industry standards and guidelines
- guidance produced by the European Commission
- guidance produced by HSE
HSE says that in most cases you should not need a consultant, and should find enough information from current sources. It says that for many businesses, consulting its guide to the Regulations (HSG281) will be enough to show that exposure does not exceed the ELVs. HSE says measurements or calculations should be needed only by employers using the more powerful equipment or the highest currents, where existing information cannot show that the health effect ELVs are not exceeded. It recommends asking your supplier if you need more information.
You must review the assessment when there is reason to suspect it is no longer valid, or when there has been a significant change in the matters it relates to. Make the changes needed to keep it suitable and sufficient.
Keep exposure within the limits
The ELVs are the limits in the Schedule. A sensory effect is a transient disturbance in sensory perception or a minor and temporary change in brain function. A health effect is a direct biophysical effect that is potentially harmful to health. HSE says sensory effects include nausea, vertigo and flickering sensations in peripheral vision. It says health effects include shocks, nerve stimulation and heating effects.
You must ensure that your employees are not exposed to EMF levels in excess of the ELVs. The duty does not apply, or is relaxed, in these cases:
- Sensory effect ELVs, but not health effect ELVs, may be exceeded during work activities where you have taken the applicable safety measures in the Schedule.
- The duty does not apply to an activity with a suitable and sufficient exposure limitation system in place, where a member of Her Majesty's armed forces or a visiting force acting in that capacity carries it out, or a civilian working with such a person carries it out, or it takes place on premises or part of premises under the control of the Secretary of State for the purposes of the Ministry of Defence or the service authorities of a visiting force.
- The duty does not apply to the development, testing, installation, use and maintenance of, or research related to, magnetic resonance imaging (MRI) equipment for patients in the health sector, but only where exposure of employees is as low as is reasonably practicable and employees are protected against any health effects and safety risks related to that exposure.
- The duty does not apply to a work activity for which HSE has issued an exemption certificate, while the conditions of the certificate are met and the certificate has not expired or been revoked.
You may exceed a sensory effect ELV during an employee's shift only if the exposure is temporary and you give the employee adequate information about the possible sensory effects. The further conditions depend on the field:
- For static magnetic fields from 0 to 1 Hz, you have also adopted protection measures that minimise, so far as is reasonably practicable, the sensory effects of movement in static magnetic fields, including nausea and vertigo. Where an employee reports one of those effects, you update the exposure assessment and the protection measures where necessary.
- For time-varying fields from 1 to 400 Hz, you have also prevented hazardous spark discharges, and contact currents above those in Table AL5 of the Schedule, through information and training and suitable technical and personal protection measures. Where an employee reports a sensory effect, you update the risk assessment where necessary.
- For fields from 300 MHz to 6 GHz, where an employee reports a sensory effect, you update the risk assessment where necessary.
Make an action plan
You must make and implement a suitable and sufficient action plan to ensure that you comply with the ELVs. The duty does not apply where:
- your most recent exposure assessment demonstrates that you comply with the duty to keep exposure within the ELVs
- the activity has a suitable and sufficient exposure limitation system in place and is carried out by a member of Her Majesty's armed forces or a visiting force acting in that capacity, by a civilian working with such a person, or on premises or part of premises under the control of the Secretary of State for the purposes of the Ministry of Defence or the service authorities of a visiting force
- the activity is the development, testing, installation, use or maintenance of, or research related to, MRI equipment for patients in the health sector, and exposure of employees is as low as is reasonably practicable and employees are protected against any health effects and safety risks related to that exposure
- HSE has exempted the work activity from the action plan duty by certificate
The plan must include consideration of, where relevant:
- other working methods that entail lower exposure to EMF
- replacement equipment designed to reduce the level of exposure
- technical measures to reduce the emission of EMF, including where necessary interlocks, screening or similar health protection mechanisms
- demarcation and access control measures
- maintenance programmes for work equipment, workplaces and workstation systems
- the design and layout of workplaces and workstations
- limitations on the duration and intensity of exposure
- the availability of suitable personal protective equipment
If exposure still exceeds any ELV despite the measures in your plan, you must, as soon as is reasonably practicable, identify and implement the changes to the plan that are necessary to comply with the ELVs.
Assess the risks and reduce them
You must make a suitable and sufficient assessment of the risks to employees from their exposure to EMF. You must also ensure that, so far as is reasonably practicable, the risks it identifies are eliminated or reduced to a minimum. Neither duty applies where all of these are true:
- your most recent exposure assessment demonstrates that employees are not exposed to EMF levels in excess of the ELVs
- the indirect effect ALs are not exceeded, meaning the Low ALs in Table AL1 and the ALs in Tables AL5 to AL7 of the Schedule
- you have no employees at particular risk
An indirect effect is an effect caused by the presence of an object or substance in an EMF that may present a safety or health hazard. HSE gives interference with implanted or body-worn medical devices, and the uncontrolled attraction of ferromagnetic objects, as examples.
In the Regulations, an employee at particular risk is either:
- an employee who has declared to you a condition that may lead to a higher susceptibility to the potential effects of exposure to EMF
- an employee who works in close proximity to electro-explosive devices, explosive materials or flammable atmospheres
HSE gives expectant mothers, and employees with active or passive implanted or body-worn medical devices, as examples of employees at particular risk. The Regulations do not name either example. HSE asks employers to take such employees into account.
The risk assessment must include consideration of, where relevant:
- the ALs and ELVs
- the frequency range, level, duration and type of exposure, including its distribution over the employee's body and the workplace
- direct biophysical effects
- replacement equipment designed to reduce the level of exposure
- information from any health surveillance or medical examinations you provide
- information from the manufacturer or distributor of the equipment
- multiple sources of exposure
- simultaneous exposure to multiple frequency fields
- indirect effects
- any effects on employees at particular risk
- other health and safety related information
The risks assessed do not include the risk of effects caused by contact with live conductors, caused by multiple and separate instances of exposure, or that continue to develop after exposure has ceased.
You must review the risk assessment when there is reason to suspect it is no longer valid, or when there has been a significant change in the matters it relates to. Make the changes needed to keep it suitable and sufficient.
The measures you take to eliminate or reduce the risks must be based on the general principles of prevention in Schedule 1 to the Management of Health and Safety at Work Regulations 1999. They must take into account technical progress, the potential to restrict access to parts of the workplace, and the availability of measures to control the production of EMF at source.
Give information and training
You must provide relevant information and training to any employees who are likely to be subjected to the risks identified in your most recent risk assessment. This includes information and training on:
- the measures you have taken to eliminate or reduce the risks
- the concepts and values of the ALs and ELVs and the possible risks associated with them
- the possible indirect effects of exposure
- the results of your most recent exposure assessment
- how to detect and report sensory and health effects
- the circumstances in which employees are entitled to health surveillance and medical examinations
- safe working practices
- any additional measures taken for employees at particular risk
HSE says the information should also be made available to employees' safety representatives as appropriate.
Provide health surveillance
You must ensure that health surveillance and medical examinations are provided, as appropriate, to any employee who both:
- is exposed to EMF levels in excess of the health effect ELVs
- reports experiencing a health effect to you
Exposure above a sensory effect ELV alone does not trigger the duty. You must provide the surveillance or examination during reasonable hours chosen by the employee. You must keep a suitable record of any health surveillance and medical examinations you provide, whatever the size of your business. HSE says surveillance is likely to be necessary only in very limited circumstances, because there is no well-established scientific evidence of long-term health effects.
Keep records
If you employ 5 or more employees, you must record:
- the significant findings of the most recent exposure assessment
- where an action plan is required, the most recent action plan
- where a risk assessment is required, the significant findings of the most recent risk assessment
Use an HSE exemption
HSE may by written certificate exempt employers from the duties to keep exposure within the ELVs and to make an action plan, in relation to one or more work activities. Every other duty still applies. An exemption must be limited in time and subject to the conditions that exposure of employees to EMF is as low as is reasonably practicable, and employees are protected against any health effects and safety risks related to that exposure. HSE may amend or revoke an exemption at any time.
HSE says the certificate attaches to the work activity, not to an individual business. If your activity is on the certificate, you do not have to apply to HSE, and an individual certificate for your business is not necessary. HSE says you can download a copy of the certificate for your records, and that meeting the conditions is your responsibility. If you do not or cannot meet them, the exemption does not apply to you.
HSE says that for an exempted activity you do not have to use measurements or calculations in your exposure assessment, or make an action plan. It says you must still carry out and periodically review a risk assessment of the direct and indirect risks, and give relevant information and training to workers.
If your work activity is not on the certificate but you think it should be, you can apply to HSE for the activity to be added. HSE says the request should include:
- the nature of the work activity, including what process is carried out and why the exposure limits cannot be met
- a description of the equipment, including frequencies, emissions, power levels, and the measures taken on equipment and operator positioning and screening
- a description of the operating cycles, such as duty cycles, shifts or the temporary nature of the exposure
- an account of the preventative actions taken to keep exposure as low as is reasonably practicable
- why continuing the activity is essential to the business, whether commercially or otherwise
HSE says to send the application by email to its Radiation policy team, and that it may ask for more information. It aims to decide within 12 weeks of receiving all the information it needs.
Penalties for breach
Contravening the Regulations is an offence under section 33(1)(c) of the Health and Safety at Work etc. Act 1974. The maximum penalties are:
- in England and Wales, on summary conviction, imprisonment for up to 12 months (6 months for an offence committed before 2 May 2022) or an unlimited fine, or both
- in England and Wales, on conviction on indictment, imprisonment for up to 2 years, a fine, or both
- in Scotland, on summary conviction, imprisonment for up to 12 months or a fine of up to £20,000, or both
- in Scotland, on conviction on indictment, imprisonment for up to 2 years, a fine, or both
Legal basis
Primary legislation and key regulations
Official guidance
A guide to the Control of Electromagnetic Fields at Work Regulations 2016 (HSG281) (opens in a new tab)
HSE · Great Britain
Introduction to Electromagnetic fields (EMFs) and employers’ duties (opens in a new tab)
HSE · Great Britain
The Control of Electromagnetic Fields at Work Regulations (opens in a new tab)
HSE · Great Britain
Exemptions from exposure limits in the Control of Electromagnetic Fields at Work Regulations (opens in a new tab)
HSE