UK Statutory Instrument 1992 United Kingdom

The Cholsey and Wallingford Light Railway (Extension and Amendment) Order 1992

At a glance

What's here

4 compliance obligations

Who this Act binds

Plus 1 non-business duty on Crown ministers, regulators, local authorities or tribunals — shown collapsed under each section below.

What this Act requires

Sections that create concrete duties on businesses or carry penalties. Procedural and definitional sections are folded into the “Browse other sections” expander at the bottom of each group. Click any section title to read the source text on legislation.gov.uk.

Schedules

s.sch003

The intermittent red lights shall continue to show and the...

  • Switch off level crossing warning lights and sounds before barriers reach 45°
s.sch003

The Society shall give notice in writing to the Secretary...

Other duties (1) — Crown / regulator
  • Notify Secretary of State when crossing works are complete, then arrange inspection Crown / Minister / Government department
Browse 50 other Schedules — structural / supplementary
s.sch003

Particulars of the Gates, Traffic Signsand Other Protective Equipment at the AccommodationWork Stage.

s.sch003

A stop board of standard railway design displaying the words...

s.sch003

An advance warning board of standard railway design shall be...

s.sch003

Particulars of the Barriers and Other Protective Equipment when the Road is Open to the Public.

s.sch003

When lowered the barriers shall be as nearly horizontal as...

s.sch003

When the barriers are fully lowered their uppermost surfaces shall...

s.sch003

When in the fully raised position the barriers shall be...

s.sch003

The barriers shall be as light as possible but shall...

s.sch003

The barriers shall display on both front and rear faces...

s.sch003

Suitable screening shall be provided for each barrier machine to...

s.sch003

Three electric lamps, each of not less than 5 watts...

s.sch003

When closed to road vehicles the gates shall extend across...

s.sch003

A traffic light signal as prescribed by Regulation 31(4) of...

s.sch003

A lamp which when illuminated shows a symbol of the...

s.sch003

An audible warning device shall be provided on or adjacent...

s.sch003

A reflectorised stop line of the size, colour and type...

s.sch003

A reflectorised pedestrian stop line of the size, colour and...

s.sch003

Where the specified road passes over the crossing reflectorised edge...

s.sch003

The right hand edge of each of the carriageways over...

s.sch003

A traffic sign of the size, colour and type shown...

s.sch003

A traffic sign of the size, colour and type shown...

s.sch003

A telephone mounted in a cabinet and connected to the...

s.sch003

The uppermost surfaces of the gates shall be not less...

s.sch003

Any lighting which is provided shall be at least to...

s.sch003

A railway signal shall be provided on each railway approach...

s.sch003

Facilities shall be provided at the crossing to operate the...

s.sch003

Lighting shall be provided as necessary so that during the...

s.sch003

Two independent power supplies shall be provided at the crossing,...

s.sch003

A standard level crossing speed restriction board, which shall be...

s.sch003

An advance warning board of standard railway design shall be...

s.sch003

Cattle-cum-trespass guards of standard railway design shall be provided adjacent...

s.sch003

Conditions and Requirements to be observed by the Society at the Accommodation Work Stage.

s.sch003

The gates shall be kept constantly closed across the accommodation...

s.sch003

The gates shall open outwards away from the railway and,...

s.sch003

The gates shall be secured in the closed position on...

s.sch003

Drivers shall bring their trains to a halt at the...

s.sch003

Conditions and Requirements to be observed by the Society when the Road is Open to the Public.

s.sch003

The barriers shall be kept in the fully raised position...

s.sch003

When a train either occupies a track circuit or operates...

s.sch003

Not less than 27 seconds shall elapse between the time...

s.sch003

After a train has passed one of the standard level...

s.sch003

In the event of a failure of both intermittent red...

s.sch003

If either barrier fails to rise from the lowered position...

s.sch003

Each gate shall be provided with a suitable mechanism at...

s.sch003

Should a total power failure occur, provided the barriers have...

s.sch003

If the white railway signal mentioned in paragraph 31 above...

s.sch003

The gates shall be as light as possible but shall...

s.sch003

The framework of the gates shall be comprised of parallel...

s.sch003

The gates shall each display a semi-circular plate of Red...

s.sch003

A sign shall be provided approximately five metres before the...

s.art008

As to public liability insurance

  • Maintain public liability insurance of at least £2 million before operating the railway
s.art010

Construction of public level crossing

  • Provide and maintain level crossing protective equipment
Browse 11 other sections — procedural / definitional / commencement
s.art001

Citation and commencement

s.art002

Interpretation

s.art003

Incorporation and application of enactments: amendment of Order

s.art004

Power to make Railway

s.art005

Land required in connection with Railway No. 1 or Railway No. 2

s.art006

Gauge of railway and motive power

s.art007

Restriction of weight on rails and of speed: conveyance of passengers

s.art009

Existing railway redefined

s.art011

As to public footpath level crossings

s.art012

For protection of public gas suppliers

s.art013

For protection of Southern Electric plc

Explore more

Browse legislation

Find other UK business legislation with related guidance.