THE ELECTRICITY SAFETY, QUALITY AND CONTINUITY REGULATIONS (NORTHERN IRELAND) 2012

Status
In Force
Penalty ceiling
Regulated

Does it bind you?

Business-side roles with duties under this instrument.

Distributor19 Any Person1

Other Acts binding the same actors

If a role above is yours, these are the other instruments that most often bind it.

Distributor — also bound by 182 other Acts
Any Person — also bound by 2340 other Acts

What it requires

Regulations creating concrete business duties or carrying penalties, grouped as the instrument is structured. Titles link to the source text — blue means you’re leaving for legislation.gov.uk.

s.003 General adequacy of electrical equipment (opens in a new tab) Regulated
  • Ensure your electrical equipment is safe, sufficient, and protected against risksDistributor
s.004 Duty of co-operation (opens in a new tab) Regulated
  • Disclose information and co-operate with other electricity industry participantsDistributor
s.005 Inspection of networks (opens in a new tab) Regulated
  • Inspect your electricity network and keep records for 10 yearsDistributor
s.006 Electrical protection (opens in a new tab) Regulated
  • Apply protective devices to your network to prevent dangerous current flowDistributor
s.007 Continuity of the supply neutral conductor and earthing connections (opens in a new tab) Regulated
  • Take all reasonable precautions to ensure continuity of the neutral conductor and do not install protective devices on itDistributor
s.008 General requirements for connection with earth (opens in a new tab) Regulated
  • Keep your network properly earthed to prevent dangerDistributor
s.009 Protective multiple earthing (opens in a new tab) Regulated
  • Connect neutral conductors to earth on low-voltage combined neutral/earth networksDistributor
s.010 Earthing of metalwork (opens in a new tab) Regulated
  • Earth metalwork associated with your network equipmentDistributor
s.011 Substation safety (opens in a new tab) Regulated
  • Ensure substation safety with enclosures, signs and fire precautionsDistributor
s.012 General restriction on the use of underground cables (opens in a new tab) Regulated
  • Don't use non-compliant underground cables or equipmentDistributor
s.016 General restriction on the use of overhead lines (opens in a new tab) Regulated
  • Do not use non-compliant overhead lines or exceed 400,000 voltsDistributor
s.021 Avoidance of interference with or interruption of supply caused by trees (opens in a new tab) Regulated
  • Maintain clearance between overhead lines and trees to prevent supply interruptionsDistributor
s.024 Precautions against supply failure (opens in a new tab) Regulated
  • Design and operate network to minimise supply interruptions and fault impactDistributor
s.025 Equipment on a consumer’s premises (opens in a new tab) Regulated
  • Ensure safety, marking and neutral provision of equipment on consumer premisesDistributor
s.026 Connections to installations or to other networks (opens in a new tab) Regulated
  • Get distributor consent before connecting to the networkAny Person
s.027 Disconnection of supply, refusal to connect and resolution of disagreements (opens in a new tab) Regulated
  • Follow correct disconnection and reconnection procedureDistributor
s.028 Declaration of phases, frequency and voltage at supply terminals (opens in a new tab) Regulated
  • Declare supply characteristics and maintain permitted variationsDistributor
s.029 Information to be provided on request (opens in a new tab) Regulated
  • Provide electrical information to anyone with reasonable cause on requestDistributor
s.033 Notification of certain interruptions of supply (opens in a new tab) Regulated
  • Notify the Department of certain power supply interruptionsDistributor
s.035 Networks, equipment or installations in breach of Regulations (opens in a new tab) Regulated
  • Comply with Department notice to remove danger, interference or interruptionDistributor
17 other provisions — procedural and definitional