Retained EU Law SI 2015/1095 United Kingdom

Commission Regulation (EU) 2015/1095 of 5 May 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for professional refrigerated storage cabinets, blast cabinets, condensing units and process chillers (Text with EEA relevance)

Status
In Force
Penalty ceiling
Regulated

Does it bind you?

Business-side roles with duties under this instrument.

Manufacturer3

Plus 1 duty on the regulator, Crown ministers and public bodies — folded into the section list below.

Other Acts binding the same actors

If a role above is yours, these are the other instruments that most often bind it.

Manufacturer — also bound by 502 other Acts

What it requires

Regulations creating concrete business duties or carrying penalties, grouped as the instrument is structured. Titles link to the source text — blue means you’re leaving for legislation.gov.uk.

uri:annex/ii/division/2 uri:annex/ii/division/2 Regulated
  • Provide required product details and technical documentation for your refrigeration equipmentManufacturer
uri:annex/v/division/2 uri:annex/v/division/2 Regulated
  • Provide prescribed product information for condensing unitsManufacturer
uri:annex/vii/division/2 uri:annex/vii/division/2 Regulated
  • Provide detailed product information with process chillers from 1 July 2016Manufacturer
uri:annex/x uri:annex/x Regulated
Other duties (1) — Crown / regulator
  • Great Britain authorities must verify product compliance using specified tolerancesStatutory regulator
37 other provisions — procedural and definitional
uri:annex/vii/division/1 uri:annex/vii/division/1
uri:annex/xi uri:annex/xi
s.annex iii para.1 For the calculation of the energy efficiency index (EEI) of...
s.annex iii para.10 Table 2 M and N coefficient values Category Value for...
s.annex iii para.2 The EEI is calculated as:
s.annex iii para.3 EEI = (AEC/SAEC) × 100
s.annex iii para.4 Where:
s.annex iii para.5 AEC = E24h × af × 365
s.annex iii para.6 AEC annual energy consumption of the cabinet in kWh/year E24h...
s.annex iii para.7 SAEC = M × Vn + N
s.annex iii para.8 SAEC standard annual energy consumption of the cabinet in kWh/year...
s.annex iii para.9 M and N are given in the Table 2.
s.annex i para.1 For the purposes of Annexes II to XII the following...
s.annex ix para.1 The verification tolerances defined in this Annex relate only to...
s.annex ix para.2 When verifying the compliance of a product model with the...
s.annex ix para.4 The Great Britain authorities shall use the measurement and calculation...
s.annex ix para.5 The Great Britain authorities shall only apply the verification tolerances...
s.annex ix para.6 Table 8 Verification tolerances Parameters Verification tolerances Net volume The...
s.annex vi para.1 Table 6 Variations of outdoor temperatures across the year under...
s.annex xi para.1 The verification tolerances defined in this Annex relate only to...
s.annex xi para.2 When verifying the compliance of a product model with the...
s.annex xi para.4 The Great Britain authorities shall use the measurement and calculation...
s.annex xi para.5 The Great Britain authorities shall only apply the verification tolerances...
s.annex xi para.6 Table 10 Verification tolerances Parameters Verification tolerances Seasonal energy performance...
s.annex x para.1 The verification tolerances defined in this Annex relate only to...
s.annex x para.2 When verifying the compliance of a product model with the...
s.annex x para.4 The Great Britain authorities shall use the measurement and calculation...
s.annex x para.5 The Great Britain authorities shall only apply the verification tolerances...
s.annex x para.6 Table 9 Verification tolerances Parameters Verification tolerances The seasonal energy...
s.art001 Subject matter and scope
s.art002 Definitions
s.art003 Ecodesign requirements and timetable
s.art004 Conformity assessment
s.art005 Verification procedure for market surveillance purposes
s.art006 Indicative benchmarks
s.art007 Review
s.art008 Entry into force

Duty extraction and severity labels are Guvnor’s analysis of the instrument, not the instrument itself. Always verify against the linked source text.