Retained EU Law 2014 United Kingdom

Commission Regulation (EU) No 1253/2014 of 7 July 2014 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for ventilation units (Text with EEA relevance)

At a glance

What's here

3 compliance obligations

What this Act requires

Sections that create concrete duties on businesses or carry penalties. Procedural and definitional sections are folded into the “Browse other sections” expander at the bottom of each group. Click any section title to read the source text on legislation.gov.uk.

uri:annex/iv/division/3

uri:annex/iv/division/3

  • Provide detailed disassembly instructions for recyclable parts on your website
uri:annex/v/division/3

uri:annex/v/division/3

  • Make recycling instructions available on your free-access website
s.art004

Information requirements

  • Provide product information for ventilation units (RVUs and NRVUs)
Browse 34 other sections — procedural / definitional / commencement
uri:annex/ii/division/1

uri:annex/ii/division/1

uri:annex/iii/division/2

uri:annex/iii/division/2

uri:annex/iv/division/1

uri:annex/iv/division/1

uri:annex/iv/division/2

uri:annex/iv/division/2

uri:annex/v/division/1

uri:annex/v/division/1

uri:annex/v/division/2

uri:annex/v/division/2

s.annex i para.1

Definitions applicable for the purposes of Annexes II to IX...

s.annex i para.2

Definitions: ‘specific energy consumption (SEC)’ (expressed in kWh/(m2.a)) means a...

s.annex ix para.1

NRVUs shall be tested and calculated using a ‘reference configuration’...

s.annex ix para.2

Dual use units shall be tested and calculated in the...

s.annex viii para.1

The specific energy consumption SEC is calculated with the following...

s.annex viii para.2

SEC = t a × pef × q net ×...

s.annex viii para.3

where:

s.annex viii para.4

SEC is Specific Energy Consumption for ventilation per m2 heated...

s.annex viii para.5

SPI and ηt are values derived from tests and calculation...

s.annex viii para.6

Other parameters and their defaults are given in Table 1....

s.annex vii para.1

Residential ventilation units:

s.annex vii para.2

SEC: – 42 kWh/(m2.a) for BVUs, and – 27 kWh/(m2.a)...

s.annex vii para.3

Non-residential ventilation units:

s.annex vii para.4

SFPint: 150 W/(m3/s) below the Tier 2 limit for NRVUs...

s.annex vi para.1

The verification tolerances defined in this Annex relate only to...

s.annex vi para.2

When verifying the compliance of a product model with the...

s.annex vi para.3

The Great Britain authorities shall verify one single unit of...

s.annex vi para.4

The Great Britain authorities shall use the measurement and calculation...

s.annex vi para.5

The Great Britain authorities shall only apply the verification tolerances...

s.annex vi para.6

Table 1 Verification tolerances Parameters Verification tolerances SPI The determined...

s.art001

Subject matter and scope

s.art002

Definitions

s.art003

Ecodesign requirements

s.art005

Conformity assessment

s.art006

Verification procedure for market surveillance purposes

s.art007

Benchmarks

s.art008

Review

s.art009

Entry into force