- Status
- In Force
- Penalty ceiling
- Regulated
Does it bind you?
Business-side roles with duties under this instrument.
Manufacturer1
Other Acts binding the same actors
If a role above is yours, these are the other instruments that most often bind it.
Manufacturer — also bound by 502 other Acts
Measuring Instruments Regulations 2016
85 duties
Human Medicines Regulations 2012
75 duties
What it requires
Regulations creating concrete business duties or carrying penalties, grouped as the instrument is structured. Titles link to the source text — blue means you’re leaving for legislation.gov.uk.
uri:annex/ii/division/2/division/13
uri:annex/ii/division/2/division/13
Regulated
- Describe technical parameters for extreme-temperature water pumpsManufacturer
29 other provisions — procedural and definitional
uri:annex/ii/division/1/division/b
uri:annex/ii/division/1/division/b
s.annex iii para.1
For the purposes of compliance and verification of compliance with...
s.annex iii para.10
η OL min, requ = 0,985 × η BEP min,...
s.annex iii para.11
All efficiencies are based on full (untrimmed) impeller. Vertical multistage...
s.annex iii para.2
The hydraulic pump efficiency, as defined in Annex I, is...
s.annex iii para.3
The formula for calculating the required minimum efficiency at best...
s.annex iii para.4
Where,
s.annex iii para.5
x = ln (ns); y = ln (Q) and ln...
s.annex iii para.6
The value of C depends on the pump type and...
s.annex iii para.7
Table Minimum efficiency index (MEI) and its corresponding C-value depending...
s.annex iii para.8
The requirements for part load (PL) and over load (OL)...
s.annex iii para.9
η PL min, requ = 0,947 × η BEP min,...
s.annex i para.1
For the purpose of Annexes II to V, the following...
s.annex i para.2
‘Impeller’ means the rotating component of a rotodynamic pump which...
s.annex iv para.1
The verification tolerances defined in this Annex relate only to...
s.annex iv para.2
When verifying the compliance of a product model with the...
s.annex iv para.3
The Great Britain authorities shall verify one single unit of...
s.annex iv para.4
The Great Britain authorities shall use the measurement and calculation...
s.annex iv para.5
The Great Britain authorities shall only apply the verification tolerances...
s.annex iv para.6
Table 2 Verification tolerances Parameters Verification tolerances Efficiency at BEP...
s.annex v para.1
At the time of entry into force of this Regulation,...
s.art001
Subject matter and scope
s.art002
Definitions
s.art003
Ecodesign requirements
s.art004
Conformity assessment
s.art005
Verification procedure for market surveillance purposes
s.art006
Indicative benchmarks
s.art007
Revision
s.art008
Entry into force
Duty extraction and severity labels are Guvnor’s analysis of the instrument, not the instrument itself. Always verify against the linked source text.