About this learning path
This journey guides you through the fire safety duties that apply to building owners following the Fire Safety Act 2021 and Fire Safety (England) Regulations 2022. These laws were introduced in response to the Grenfell Tower tragedy and significantly expand your responsibilities.
This learning path is for:
- Freeholders and building owners
- Resident Management Companies (RMCs)
- Managing agents responsible for fire safety
- Housing associations and social landlords
- Anyone who may be a 'responsible person' for a multi-occupied residential building
By the end of this journey, you will understand who is legally responsible for fire safety, what assessments you must conduct, what inspections and maintenance are required, and how to communicate with residents and the Fire and Rescue Service.
Part 1: Understanding who you are in fire safety law
Before you can meet your fire safety duties, you need to know whether you are a 'responsible person' under the Regulatory Reform (Fire Safety) Order 2005. Getting this wrong can mean criminal liability falls on the wrong person, or that nobody takes responsibility at all.
The responsible person is whoever has control of the building. In multi-occupied residential buildings, this is often the freeholder, but can also be a management company, managing agent, or Resident Management Company.
Identify the responsible person for your building
Detailed guide to determining who is legally responsible for fire safety under Article 3 of the Fire Safety Order, including multiple responsible person scenarios and the Article 22 duty to cooperate
Part 2: Fire risk assessment fundamentals
Once you know you are a responsible person, your primary duty is to conduct a fire risk assessment for the areas under your control. This is not optional - it is a legal requirement under Article 9 of the Fire Safety Order.
Since the Fire Safety Act 2021, fire risk assessments for multi-occupied residential buildings must explicitly cover external walls, cladding, balconies, windows, and flat entrance doors. Many pre-2022 assessments do not meet this expanded scope.
Conduct a fire risk assessment
Step-by-step guide to the 5-step fire risk assessment process, including when to use a professional assessor and how often to review your assessment
Part 3: External wall assessment requirements
The Grenfell Tower fire spread rapidly via the building's external cladding. The Fire Safety Act 2021 now explicitly requires your fire risk assessment to include external walls - covering cladding systems, insulation, balconies, windows, and anything attached to the exterior.
For buildings with complex cladding, you may need an External Wall Survey (EWS1) conducted by a qualified fire engineer. EWS1 ratings range from A1 (no combustible materials) to B2 (extensive remediation required).
Assess external wall fire safety
Your legal duties for external wall assessment, when EWS1 surveys are needed, understanding EWS1 ratings, finding qualified fire engineers, and what to do if remediation is required
Part 4: Fire door inspection duties
Fire doors are critical to compartmentation - the fire safety strategy that contains fire and smoke within defined areas. The Fire Safety (England) Regulations 2022 introduced mandatory inspection frequencies for buildings 11 metres or higher.
If your building meets this height threshold, you must inspect communal fire doors quarterly and make best endeavours to inspect flat entrance doors annually. Keep records of all inspections and any remedial actions.
Inspect and maintain fire doors
Complete guide to fire door inspection requirements under the Fire Safety (England) Regulations 2022, including what to check, record keeping, and what happens if residents refuse access
Part 5: High-rise specific requirements
If your building is a 'high-rise residential building' - 18 metres or higher, or at least 7 storeys - you have additional duties under the Fire Safety (England) Regulations 2022. These requirements implement key recommendations from the Grenfell Tower Inquiry Phase 1 report.
High-rise buildings must have secure information boxes, floor plans provided to the Fire and Rescue Authority, wayfinding signage for firefighters, and enhanced resident information duties.
Meet high-rise building requirements
Full guide to the additional requirements for high-rise residential buildings (18m+ or 7+ storeys) including secure information boxes, floor plans, wayfinding signage, and building information duties
Part 6: Providing information to your Fire and Rescue Service
For high-rise buildings, you have specific duties to provide building information to your local Fire and Rescue Authority. This helps firefighters plan their response to incidents and navigate your building safely.
You must provide electronic floor plans, external wall construction information, and details of fire safety equipment. This information must be kept up to date and provided promptly on request.
Provide building information to your Fire and Rescue Service
How to meet your legal duty to provide secure information boxes, floor plans, and external wall information to your Fire and Rescue Authority
Part 7: Communicating fire safety to residents
You must provide fire safety information to all residents of your building. This is a specific duty under Regulation 9 of the Fire Safety (England) Regulations 2022 and applies to all multi-occupied residential buildings, regardless of height.
Residents need to understand the building's evacuation strategy, what to do if they discover a fire, how fire doors work, and how to report fire safety concerns. Getting this communication right can save lives.
Create fire safety communications for residents
How to meet your duty to inform residents about fire safety measures, evacuation strategies, fire door importance, and reporting concerns - including accessibility considerations
Enforcement and penalties
Fire safety breaches are criminal offences with serious penalties. Since the Grenfell Tower fire, enforcement has intensified significantly. Fire and Rescue Authorities are conducting more inspections and prosecuting more cases involving residential buildings.
Relationship with the Building Safety Act 2022
If your building is 18 metres or higher, or has 7 or more storeys, you likely also have duties under the Building Safety Act 2022. This creates additional requirements enforced by the Building Safety Regulator (part of HSE), including registration, Accountable Person duties, and safety case reports.
You must comply with both the Fire Safety Act 2021 (enforced by the Fire and Rescue Authority) and the Building Safety Act 2022 (enforced by the Building Safety Regulator) separately. Meeting one does not satisfy the other.
Fire safety compliance checklist
All multi-occupied residential buildings
- Confirm you are a responsible person (or identify who is)
- Fire risk assessment covering structure, external walls, and flat entrance doors
- Fire safety information provided to all residents
- Process for residents to report fire safety concerns
Buildings 11 metres or higher (approximately 5+ storeys)
- Quarterly fire door inspections (communal areas)
- Annual fire door inspections (flat entrance doors - best endeavours)
- Records of all inspections and remedial actions
Buildings 18 metres or higher (or 7+ storeys)
- Secure information box with floor plans and contact details
- Floor plans provided to Fire and Rescue Authority
- Wayfinding signage on all floors and stairwells
- External wall construction information recorded and available
- Enhanced resident information (external wall info on request)
- Check Building Safety Act 2022 duties also apply
Further resources
GOV.UK Fire Safety (England) Regulations 2022 guidance (opens in a new tab)
Official government fact sheets and guidance documents for the Fire Safety (England) Regulations 2022
Fire Safety Act 2021 (opens in a new tab)
Full text of the Fire Safety Act 2021 on legislation.gov.uk
Fire safety in purpose-built blocks of flats (opens in a new tab)
Government guidance on fire safety management in residential blocks
Building Safety Regulator (opens in a new tab)
For buildings 18m+ or 7+ storeys, additional Building Safety Act duties may apply - check with the Building Safety Regulator