- Enforced by
- NRW
- Status
- In Force
What it defines
Regulations creating concrete business duties or carrying penalties, grouped as the instrument is structured. Titles link to the source text — blue means you’re leaving for legislation.gov.uk.
11 other provisions — procedural and definitional
s.001
Title, application and commencement
s.002
Interpretation
s.003
Making or storage of silage
s.004
Storage of slurry
s.005
Storage of fuel oil on farms
s.006
Exemptions
s.007
Notice requiring works etc.
s.008
Appeals against regulation 7 notices
s.009
Notice of construction etc.
s.010
Offences and penalties
s.011
Revocations
Schedules
Schedules
0 of 27 shown27 other schedules
s.sch001
The requirement to be satisfied in relation to a silo...
s.sch001
The base of the silo must— (a) extend beyond any...
s.sch001
The capacity of the effluent tank must not be less...
s.sch001
(1) The base of the silo must be—
s.sch001
The base and walls of the silo, its effluent tank...
s.sch001
No part of the silo, its effluent tank or channels...
s.sch001
If the silo has retaining walls— (a) the retaining walls...
s.sch001
Subject to paragraph 9, the silo, its effluent tank and...
s.sch001
If any part of an effluent tank is below ground...
s.sch002
The requirements to be satisfied in relation to a slurry...
s.sch002
(1) Subject to sub-paragraph (3), if the slurry storage tank...
s.sch002
In the case of a slurry storage tank with walls...
s.sch002
The base of the slurry storage tank, the base and...
s.sch002
The base and walls of the slurry storage tank, any...
s.sch002
The base and walls of the slurry storage tank and...
s.sch002
(1) Any facilities used for the temporary storage of slurry...
s.sch002
(1) Subject to sub-paragraph (2), the slurry storage tank must...
s.sch002
No part of the slurry storage tank or any effluent...
s.sch002
The slurry storage tank and any effluent tank, channels, pipes...
s.sch002
If the walls of the slurry storage tank are not...
s.sch003
The requirements to be satisfied in relation to a fuel...
s.sch003
The storage area must be surrounded by a bund capable...
s.sch003
The bund and the base of the area must be—...
s.sch003
Every part of any fuel storage tank must be within...
s.sch003
Any tap or valve permanently fixed to the fuel storage...
s.sch003
If fuel from the tank is delivered through a flexible...
s.sch003
No part of the fuel storage area or the bund...
Duty extraction and severity labels are Guvnor’s analysis of the instrument, not the instrument itself. Always verify against the linked source text.