UK Statutory Instrument 1996 United Kingdom

The Fertilisers (Sampling and Analysis) Regulations 1996

At a glance

What this Act requires

Sections that create concrete duties on businesses or carry penalties. Procedural and definitional sections are folded into the “Browse other sections” expander at the bottom of each group. Click any section title to read the source text on legislation.gov.uk.

Schedules

Browse 29 other Schedules — structural / supplementary
s.sch001

Apparatus designed to divide the sample into approximately equal parts...

s.sch001

A sample taken in accordance with the methods described below...

s.sch001

An inspector who intends to take a sample in accordance...

s.sch001

The sampling apparatus shall be made of materials which cannot...

s.sch001

In the case of a sampling spear its dimensions shall...

s.sch001

Notwithstanding the provisions of these Regulations, a sampling spear shall...

s.sch001

Mechanical apparatus may be used for the sampling of moving...

s.sch002

The stoichiometric EDTA-metal ratio in the complexometric analyses is always...

s.sch002

Complexometric indicators are often sensitive to air. The solution may...

s.sch002

The metal-indicator complexes are often relatively stable and it may...

s.sch002

The colour change of the indicator must not be observed...

s.sch002

This analysis requires a certain amount of experience. The task...

s.sch002

If an EDTA solution of guaranteed strength is used (Titrisol,...

s.sch002

The solutions containing potassium cyanide must not be poured down...

s.sch002

Solid fertilisers: the preparation of a final sample received at...

s.sch002

Fluid fertilisers: the final sample is mixed by shaking to...

s.sch002

Catalyst mixture: 1,000 g potassium sulfate and 50 g copper...

s.sch002

Indicator solutions: (3.12.1) Mixed indicator: mix 50 ml of 2...

s.sch002

pH indicator paper, wide range.

s.sch002

Indicator solutions: (4.29.1) Mixed indicator solution: Solution A: dissolve 1...

s.sch002

Indicator papers: Litmus, bromothymol blue (or other papers sensitive in...

s.sch002

Ethanol or methanol: solution 95%.

s.sch002

Sintered glass crucibles, diameter of pores 5 to 15 microns....

s.sch002

Schedule 2 para.7.7

s.sch002

Schedule 2 para.7.8

s.sch002

Titration in the presence of calcein or of calcon carbonic...

s.schedule/2/part/2/crossheading/preparation/of/the/

WARNING

s.schedule/2/part/i/crossheading/determination/of/am

TABLE FOR METHOD 2

s.schedule/2/part/i/crossheading/extraction/and/dete

WARNING

Browse 79 other sections — procedural / definitional / commencement
s.001

Title, commencement and interpretation

s.002

Prescribed amount for the purposes of the definition of sampled portion

s.003

Manner of taking, marking, sealing and fastening up of samples

s.003

Sample divider (optional).

s.003

Demineralised water, freshly boiled to remove carbon dioxide.

s.003

Sieves with apertures of 0.2 mm and 0.5 mm.

s.003

250 ml flasks, stoppered.

s.003

Porcelain pestle and mortar or grinder.

s.003

Ureic nitrogen, either: (3.5.1) By conversion using urease, into ammonia,...

s.003

Sodium hydroxide: 0.1 M standard solution.

s.003

Bromophenol blue: solution of 0.4 grams per litre in water....

s.003

Phenolphthalein: solution of 2 grams per litre in 60% by...

s.003

Soda lime: particle dimensions, about 1.0 to 1.6 mm.

s.004

Methods of sending part of a sample

s.004

Hydrochloric acid solution, 50% (V/V): dilute an appropriate volume of...

s.004

Sodium or potassium hydroxide, 0.2 M solution, free from carbonates....

s.004

Stannous chloride solution: Dissolve 120 g of stannous chloride (SnCl2.2H2O)...

s.004

Sulfuric acid, concentrated (p=1.84 g/ml).

s.004

Hydrochloric acid solution: dilute an appropriate volume of hydrochloric acid...

s.004

Glacial acetic acids.

s.004

Sulfuric acid solution, approximately 30% (W/V) H2SO4.

s.004

Ferrous sulfate, crystalline, FeSO4.7H2O

s.004

Sulfuric acid, 0.05 M solution.

s.004

Octan-1-ol.

s.004

Potassium carbonate, saturated solution.

s.004

Iron powder, reduced with hydrogen (the prescribed quantity of iron...

s.004

Sodium or potassium hydroxide, 0.1 M solution, free from carbonate....

s.004

Barium hydroxide, saturated solution.

s.004

Sodium carbonate solution, 10 g per 100 ml.

s.004

Hydrochloric acid, 2 M solution.

s.004

Hydrochloric acid, 0.1 M solution.

s.004

Urease solution: Suspend 0.5 g of active urease in 100...

s.004

Xanthydrol solution, 5 g per 100 ml in ethanol or...

s.004

Copper oxide (CuO): 0.3 to 0.4 g per determination or...

s.004

Anti-bump granules washed in hydrochloric acid and ignited.

s.004

Potassium thiocyanate.

s.004

Potassium nitrate.

s.004

Ammonium sulfate.

s.004

Urea.

s.004

Sulfuric acid solution: dilute an appropriate volume of sulfuric acid...

s.004

Sodium hydroxide solution, 30 g per 100 ml, ammonia free...

s.004

Indicator solutions: Mixed indicator: (4.9.1) Solution A: dissolve 1 g...

s.005

Qualifications of agricultural analysts and deputy agricultural analysts

s.005

Distillation apparatus consisting of a round-bottomed flask of suitable capacity...

s.005

Rotary shaker, 35 to 40 turns per minute.

s.005

Rotary shaker, 35 – 40 turns per minute.

s.005

Rotary shaker, 35 – 40 turns per minute.

s.005

pH meter.

s.005

Laboratory oven.

s.006

Application of the methods of analysis

s.006

Carry out two individual determinations in quick succession on separate...

s.006

Remove particles smaller than 0.5 mm using the test sieve...

s.006

Filter the entire contents of the beaker through the funnel...

s.006

Lay two sheets of filter paper (5.5) (about 500 ×...

s.006

s.6.5

s.006

s.6.6

s.006

s.6.7

s.006

s.6.8

s.007

Form of certificate of analysis

s.007

Extraction Weigh to the nearest 0.001 g, 5 g of...

s.007

Determination Determine the phosphorus using Method 10 on an aliquot...

s.007

Preparation of the solution to be analysed. Add approximately 50...

s.007

Preparation of blank solution. Prepare a blank solution by repeating...

s.007

Preparation of calibration solutions. By diluting the standard solution (4.3)...

s.007

Measurement. Set up the spectrometer (5.1) at a wavelength of...

s.008

Modification of the Agriculture Act 1970

s.008

In certain cases, a difference may be found between the...

s.008

Before each analysis, check that the apparatus is working properly...

s.009

Revocations

Explore more

Browse legislation

Find other UK business legislation with related guidance.