UK Statutory Instrument SI 1996/1342 United Kingdom

The Fertilisers (Sampling and Analysis) Regulations 1996

Status
In Force

What it defines

Regulations creating concrete business duties or carrying penalties, grouped as the instrument is structured. Titles link to the source text — blue means you’re leaving for legislation.gov.uk.

79 other provisions — procedural and definitional
s.001 Title, commencement and interpretation
s.002 Prescribed amount for the purposes of the definition of sampled portion
s.003 Manner of taking, marking, sealing and fastening up of samples
s.003 Sample divider (optional).
s.003 Demineralised water, freshly boiled to remove carbon dioxide.
s.003 Sieves with apertures of 0.2 mm and 0.5 mm.
s.003 250 ml flasks, stoppered.
s.003 Porcelain pestle and mortar or grinder.
s.003 Ureic nitrogen, either: (3.5.1) By conversion using urease, into ammonia,...
s.003 Sodium hydroxide: 0.1 M standard solution.
s.003 Bromophenol blue: solution of 0.4 grams per litre in water....
s.003 Phenolphthalein: solution of 2 grams per litre in 60% by...
s.003 Soda lime: particle dimensions, about 1.0 to 1.6 mm.
s.004 Methods of sending part of a sample
s.004 Hydrochloric acid solution, 50% (V/V): dilute an appropriate volume of...
s.004 Sodium or potassium hydroxide, 0.2 M solution, free from carbonates....
s.004 Stannous chloride solution: Dissolve 120 g of stannous chloride (SnCl2.2H2O)...
s.004 Sulfuric acid, concentrated (p=1.84 g/ml).
s.004 Hydrochloric acid solution: dilute an appropriate volume of hydrochloric acid...
s.004 Glacial acetic acids.
s.004 Sulfuric acid solution, approximately 30% (W/V) H2SO4.
s.004 Ferrous sulfate, crystalline, FeSO4.7H2O
s.004 Sulfuric acid, 0.05 M solution.
s.004 Octan-1-ol.
s.004 Potassium carbonate, saturated solution.
s.004 Iron powder, reduced with hydrogen (the prescribed quantity of iron...
s.004 Sodium or potassium hydroxide, 0.1 M solution, free from carbonate....
s.004 Barium hydroxide, saturated solution.
s.004 Sodium carbonate solution, 10 g per 100 ml.
s.004 Hydrochloric acid, 2 M solution.
s.004 Hydrochloric acid, 0.1 M solution.
s.004 Urease solution: Suspend 0.5 g of active urease in 100...
s.004 Xanthydrol solution, 5 g per 100 ml in ethanol or...
s.004 Copper oxide (CuO): 0.3 to 0.4 g per determination or...
s.004 Anti-bump granules washed in hydrochloric acid and ignited.
s.004 Potassium thiocyanate.
s.004 Potassium nitrate.
s.004 Ammonium sulfate.
s.004 Urea.
s.004 Sulfuric acid solution: dilute an appropriate volume of sulfuric acid...
s.004 Sodium hydroxide solution, 30 g per 100 ml, ammonia free...
s.004 Indicator solutions: Mixed indicator: (4.9.1) Solution A: dissolve 1 g...
s.005 Qualifications of agricultural analysts and deputy agricultural analysts
s.005 Distillation apparatus consisting of a round-bottomed flask of suitable capacity...
s.005 Rotary shaker, 35 to 40 turns per minute.
s.005 Rotary shaker, 35 – 40 turns per minute.
s.005 Rotary shaker, 35 – 40 turns per minute.
s.005 pH meter.
s.005 Laboratory oven.
s.006 Application of the methods of analysis
s.006 Carry out two individual determinations in quick succession on separate...
s.006 Remove particles smaller than 0.5 mm using the test sieve...
s.006 Filter the entire contents of the beaker through the funnel...
s.006 Lay two sheets of filter paper (5.5) (about 500 ×...
s.006 s.6.5
s.006 s.6.6
s.006 s.6.7
s.006 s.6.8
s.007 Form of certificate of analysis
s.007 Extraction Weigh to the nearest 0.001 g, 5 g of...
s.007 Determination Determine the phosphorus using Method 10 on an aliquot...
s.007 Preparation of the solution to be analysed. Add approximately 50...
s.007 Preparation of blank solution. Prepare a blank solution by repeating...
s.007 Preparation of calibration solutions. By diluting the standard solution (4.3)...
s.007 Measurement. Set up the spectrometer (5.1) at a wavelength of...
s.008 Modification of the Agriculture Act 1970
s.008 In certain cases, a difference may be found between the...
s.008 Before each analysis, check that the apparatus is working properly...
s.009 Revocations
Schedules

Schedules

0 of 29 shown
29 other schedules
s.sch001 Apparatus designed to divide the sample into approximately equal parts...
s.sch001 A sample taken in accordance with the methods described below...
s.sch001 An inspector who intends to take a sample in accordance...
s.sch001 The sampling apparatus shall be made of materials which cannot...
s.sch001 In the case of a sampling spear its dimensions shall...
s.sch001 Notwithstanding the provisions of these Regulations, a sampling spear shall...
s.sch001 Mechanical apparatus may be used for the sampling of moving...
s.sch002 The stoichiometric EDTA-metal ratio in the complexometric analyses is always...
s.sch002 Complexometric indicators are often sensitive to air. The solution may...
s.sch002 The metal-indicator complexes are often relatively stable and it may...
s.sch002 The colour change of the indicator must not be observed...
s.sch002 This analysis requires a certain amount of experience. The task...
s.sch002 If an EDTA solution of guaranteed strength is used (Titrisol,...
s.sch002 The solutions containing potassium cyanide must not be poured down...
s.sch002 Solid fertilisers: the preparation of a final sample received at...
s.sch002 Fluid fertilisers: the final sample is mixed by shaking to...
s.sch002 Catalyst mixture: 1,000 g potassium sulfate and 50 g copper...
s.sch002 Indicator solutions: (3.12.1) Mixed indicator: mix 50 ml of 2...
s.sch002 pH indicator paper, wide range.
s.sch002 Indicator solutions: (4.29.1) Mixed indicator solution: Solution A: dissolve 1...
s.sch002 Indicator papers: Litmus, bromothymol blue (or other papers sensitive in...
s.sch002 Ethanol or methanol: solution 95%.
s.sch002 Sintered glass crucibles, diameter of pores 5 to 15 microns....
s.sch002 Schedule 2 para.7.7
s.sch002 Schedule 2 para.7.8
s.sch002 Titration in the presence of calcein or of calcon carbonic...
s.schedule/2/part/2/crossheading/preparation/of/the/ WARNING
s.schedule/2/part/i/crossheading/determination/of/am TABLE FOR METHOD 2
s.schedule/2/part/i/crossheading/extraction/and/dete WARNING

Duty extraction and severity labels are Guvnor’s analysis of the instrument, not the instrument itself. Always verify against the linked source text.