Journey
Building compliance quick check
Fast compliance verification for experienced property managers. Checklist format covering electrical, gas, water, HVAC, lifts, and energy performance requirements.
Is your building compliant?
This quick check covers the six core compliance areas for business premises. Work through each checklist to verify your current compliance status.
This is for experienced property managers who understand the regulations and need a rapid YES/NO verification before audits or lease renewals.
-
Electrical safety
Fixed installation compliance under Electricity at Work Regulations 1989.
Electrical safety compliance guide
Full requirements for fixed installations, PAT testing, and emergency lighting
-
Gas safety
Keeping gas appliances, pipework and flues safe under regulation 35 of the Gas Safety (Installation and Use) Regulations 1998.
Gas safety compliance guide
Annual inspection requirements, Gas Safe registration, and CP12 certificates
-
Air conditioning and F-gas
HVAC systems over 12kW and equipment containing fluorinated gases.
Air conditioning and F-gas compliance
TM44 inspections, F-gas leak checking, logbook requirements, and certification
-
Water systems and legionella
Legionella control under Health and Safety at Work Act and ACOP L8.
Water systems and legionella compliance
Risk assessment, temperature control, testing regime, and record keeping
-
Passenger lifts and lifting equipment
Thorough examination under LOLER 1998.
Passenger lift compliance guide
LOLER requirements, thorough examination, maintenance contracts, and safety systems
-
Energy performance and building envelope
EPC and Minimum Energy Efficiency Standards (MEES) for non-domestic properties.
Energy Performance Certificate guide
EPC requirements, MEES compliance, exemptions, and rating improvement
Asbestos, fire, heating, ventilation and lighting
Every enclosed workplace must have enough fresh or purified air, and suitable and sufficient lighting, using natural light where reasonably practicable.
Also have in place
Manage asbestos in non-domestic buildings
Surveys, the asbestos register and the management plan.
How to conduct a fire risk assessment
The steps of an assessment and what to record.
Heating system compliance for business premises
Boiler efficiency, flues and fuel storage when you replace or install heating.
Ventilation and indoor air quality requirements
How much fresh air a workplace needs and when Building Regulations apply.
Lighting requirements for business premises
Workplace lighting, emergency escape lighting and energy standards.
Failed any checks?
If you answered 'NO' to any required item:
- Electrical/Gas/Lift faults: Engage qualified contractor immediately. Do not use faulty systems.
- Overdue inspections: Book inspection within 7 days. Maintain temporary logbook until compliant.
- Missing certificates: Obtain copies from contractor or arrange re-inspection if records lost.
- EPC below E rating: Apply for exemption (if cost-effective improvements exhausted) or implement upgrades before next letting.
- Legionella control gaps: Commission risk assessment and implement control regime immediately. High risk of serious harm.
Annual compliance deadlines
- Gas safety (HSE minimum; landlords' check)
- 12 months from last inspection
- Electrical (commercial)
- 5 years (1 year high-risk)
- F-gas leak checks (large systems)
- Quarterly (3 months)
- Lift thorough examination
- 6 months
- TM44 air conditioning
- 5 years
- Legionella temperature checks
- Weekly
- EPC validity
- 10 years
When to re-check
Re-run this checklist:
- Before lease renewals or property sales
- Before HSE or local authority inspections
- After any building works or system installations
- Annually as part of insurance compliance
- When taking over management of new premises
Set calendar reminders for each inspection deadline to maintain continuous compliance.